Outdo 12 Volt 100 Amper Solar Jel Akü
Outdo 12 Volt 100 Ampere Solar Gel Battery (Deep Cycle) Features and Price
Outdo 100 Ah Gel Battery Technical Specifications
Voltage | 12V |
Capacity | 100 Ah |
Weight | 32.5 kg |
Size (LxWxH / TH) | 331x173x216 mm / 220 mm |
1H 1.75V / Cell | 55 |
3H 1.80V / Cell | 75 |
5H 1.80V / Cell | 85 |
10H 1.80V / Cell | one hundred |
20H 1.75V / Cell | 105 |
12V Solar Gel Battery General Features
2 years product warranty
Customer-oriented warranty terms
The variable charge design life is more than 8 years.
Long shelf life and waiting time
High quality, high efficiency
Safety and reliability
maintenance free
vibration resistant
Low self-discharge rate
Superior performance on long discharges
corrosion resistance
High energy density at all discharge rates
High cycle count
high temperature endurance
12V Solar Gel Battery General Usage Areas and Selection
Off-grid solar energy systems
Wind energy systems
Wind and solar hybrid systems
Solar energy storage systems for home use
solar street lighting
Traffic and navigation lights
unattended highways
Railway communication power supply and some other circuits
Signaling systems
Telecommunications systems
Industrial floor cleaning machines
For energy needs in caravans, boats and yachts
Large UPS (uninterruptible power supply) systems
mobile shops
wheelchairs
golf carts
High Technology - Leakproof - Smart Outdo Deep Discharge Gel Battery
Outdo Gel Battery; It is fully closed, maintenance free and has very low self-discharge rates. The battery cover is of the buckle type and is very easy to open. The sealing technique is quite robust and safe. When the gel electrolyte is filled, it performs much better at low and high temperatures, and it works flawlessly at -30 o C to +65 o C weather conditions. Battery plates are made of a very special material that prolongs the life of the battery. + plates produced from high purity alloys with low Ca and high tin content increase corrosion resistance. Outdo deep discharge gel batteries; Thanks to the combination of superior grid and gel technology, it provides the reliability and longevity required for daily renewable energy needs. Ideal for use in daily cyclical and harsh environmental conditions.
There is an electronic LCD screen on the gel electronic batteries, which are produced according to the new VRLA (Valve Regulated Lead Acid) battery concept, which monitors the instantaneous charge status of the battery in real time and is also used as a usage counter.
In case of low charge or capacity, there is an automatic alarm system that prompts the user to fill the battery on time, and the number of days the battery has worked is also recorded. Thanks to the audible warning, the batteries offer the correct and best performance.
Average Cycle Life by Depth of Discharge
100% Discharge - 400 Cycle
50% Discharge - 750 Cycles
30% Discharge - 1500 Cycle
Thanks to the integrated Standby Mode refill packs located under the battery cover; when the battery is nearing the end of its life, it can be easily recharged and the service life of the battery can be extended.
Things to pay attention;
- The refill pack and tube do not need to recharge the battery after use.
- The filling package used in the treatments is pure water. It does not contain harmful or corrosive substances. Care should be taken that it does not suddenly pop out while pressing and removing the cover from the bottom. After filling the water, the caps must be reinstalled.
- It should not be overcharged, it should only be charged at the appropriate time after being discharged.
- The negative terminal of the battery that will not be used for a long time should be removed or disconnected.
- For the connection to be solid; It should be checked regularly that the terminal surface or connection is clean.
- Strength; MUST NOT be checked by short-circuiting the terminal!
- It should be stored in a dry, well-ventilated place out of direct sunlight at a temperature of between 5 o C and 250 o C. Battery; It should be kept at least 2 m away from heat sources and should be checked and maintained regularly.
- The screen must be protected from impact by hard materials.
- The screen should be kept clean and dry.
- The status shown on the screen should be checked regularly.
- It should be noted whether it gives an audible warning or not.
- When the alarm occurs, the battery should be charged immediately.
- The electrolyte metal in it corrodes cotton products and stone.
- To avoid electrolyte leakage, the battery should not be reversed.
- The hydrogen produced during its operation and discharge causes explosion in fire environments.
- It should be stored and used in well-ventilated environments.
- There should be no sparks or flames in the environment.
- When used at temperatures above 45 ° C, the charging current or voltage must be reduced to extend the service life of the battery.
- The cable should not be pulled when transported with the cable. Otherwise, the cable or terminal will be damaged.
- During assembly, the connector MUST NOT be hit with a hammer!
- Care should be taken not to bump into something during transportation.